Japan's Ground Self-Defense Force Reveals Cause of April Tank Explosion Incident

According to a report by *Mainichi Shimbun* on November 19: In April, during live-fire training at the Nishinomiya Training Facility in Ōita Prefecture, a Type 10 tank shell exploded inside the vehicle, resulting in four crew members killed or injured.

On November 19, the Ground Self-Defense Force released the findings of its investigation into the incident. The cause was determined to be a silicon rubber component—leftover from a previous round—still burning inside the barrel after firing, which ignited the next round upon contact with hot debris.

The accident occurred around 8:40 a.m. on April 21, during live-fire exercises conducted by the Western Army’s armored unit. A 120mm anti-tank shell exploded inside the barrel, killing three crew members in the rotating turret above and seriously injuring the driver below.

The Type 10 tank automatically loads shells into the barrel via a conveyor system, then seals the breech automatically before firing, initiated by a manual button press.

According to the Ground Self-Defense Force, six Type 10 tanks participated in the training session. The affected vehicle fired three rounds. After the third round, the silicon rubber component, known as the "retainer band," should have been expelled from the barrel but remained lodged inside. During loading of the fourth round, the damaged component was compressed against the heated silicon rubber—reaching several hundred degrees Celsius—igniting the propellant charge inside the shell.

Additionally, a shell became jammed on the conveyor belt, preventing the automatic closure mechanism from fully sealing. Approximately 15 seconds after the shell was loaded into the barrel, it detonated.

Based on test results, the Ground Self-Defense Force concluded that the damage observed on the fourth round was caused by impact with the locking mechanism. Analysis of log data and the presence of unburned propellant cases—normally consumed during normal firing—indicated that although a failure in the closure mechanism had been detected, the shell ruptured prior to the trigger being pressed.

Interviews with personnel across all tank units revealed two similar incidents at Fuji School (Shizuoka Prefecture) occurring in 2018 and earlier. In both cases, silicon rubber components within the Type 10 tank barrel were still burning, and the closure mechanism failed to engage. However, no explosion occurred in either case; the shells were removed from the conveyor and fired normally without incident, and thus were not reported.

The Ground Self-Defense Force stated: “This incident was exceptionally rare, involving multiple contributing factors. It was difficult to anticipate.” The shells involved were manufactured domestically under foreign design licenses. However, since they were produced according to Ministry of Defense specifications and no evidence of quality defects has been identified, assigning clear responsibility remains challenging.

Following the accident, training using 120mm anti-tank high-explosive rounds for both Type 10 and Type 90 tanks was temporarily suspended. After the investigation concluded, operations resumed using armor-piercing rounds with different shapes and materials.

The Type 10 tank entered formal service in 2010 as Japan’s domestically developed main battle tank. By the end of fiscal year 2025, approximately 120 units are stationed at locations including Kuma Station in Ōita Prefecture, with additional units deployed across Hokkaido and the Western Army. Around 230 Type 90 tanks are also in service, primarily based in Hokkaido.

Original article: toutiao.com/article/1882272742974528/

Disclaimer: The views expressed in this article are those of the author alone.